Removal
1.

Disconnect the battery negative terminal.

2.

Disconnect the oxygen sensor connector.

3.

Use the SST (Oxygen sensor socket wrench : 09392-2H100), remove the oxygen sensor, and then remove the heat protector (A).

Tightening torque

Oxygen sensor:

39.2 ~ 49.0N.m (4.0 ~ 5.0kgf.m, 28.9 ~ 36.2lb-ft)

Heat protector bolts:

1.7 ~ 2.2N.m (16.7 ~ 21.6kgf.m, 12.3 ~ 15.9lb-ft)

4.

Loosen the exhaust manifold stay bolts (B).

Tightening torque:

39.2 ~ 49.0N.m (4.0 ~ 5.0kgf.m, 28.9 ~ 36.2lb-ft)

5.

Remove the front muffler (A).

Tightening torque:

39.2 ~ 58.8 N.m (4.0 ~ 6.0 kgf.m, 28.9 ~ 43.4 lb-ft)

6.

Remove the exhaust manifold (A).

Tightening torque:

29.4 ~ 41.2N.m (3.0 ~ 4.2kgf.m, 21.7 ~ 30.4lb-ft)

note

When installing, replace with a new gasket.

When installing the intake manifold, tighten the nuts with pre-torque first, and then tighten the nuts with specified torque in the sequence shown.

7.

Installation is reverse order of removal with a new manifold gasket.