Componet Location
General Description

The Evaporator sensor is located on the AC/heater boxand it detects the evaporator core temperature. When the core temperature is below the threshold value, the A/C ECU interrupts the compressor relay in order to prevent evaporator freezing.

DTC Description

The Air conditioner Control Module sets DTC B1241 if Evaporator sensor has been detected below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Voltage check

Short circuit in harness

Faulty Evaporator sensor

Faulty A/C Control Unit

Enable Conditions

IG KEY ON

Threshold value

Evaporator sensor has been detected below 01.V for 0.3 seconds.

Failsafe

Control with the value of -2℃(28.4℉)

Specification
※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

43.3

20/68

12.1

0/32

27.6

30/86

8.3

10/50

18

40/104

5.8

Diagnostic Circuit Diagram