Componet Locations
General Description

The Mode Control actuator is mounted on the AC/heater box. It adjusts position of the mode door by operating the motor. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.

DTC Description

The Air conditioner Control Module sets DTC B1249 if Feedback signal of Mode Actuator has been detected below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Voltage check

Pooer Connection in harness

Open in signal (Feedback signal), Power or Gruoud circuit

Faulty Mode Actuator

Faulty Air conditioner Control Unit

Enable Conditions

IG KEY ON

Threshold value

Feedback signal of Mode Actuator has been detected below 0.1V for 0.3 seconds

Failsafe

If the Mode actuator is placed at Vent mode right before fail detection, Actuator is operated and fixed to Vent Mode Postion.

The others mode are selected, Actuator is moved to DEF mode position

Specification
※ Voltage value of potentiometer as a function of mode door position.

Mode Door Position

Voltage

VENT

0.3±0.15V

BI-LEVEL

1.4±0.4V

FLOOR

2.5±0.4V

MIX

3.6±0.4V

DEF

4.7±0.15V

Diagnostic Circuit Diagram
Яндекс.Метрика