Inspection
1.

Ignition "OFF"

2.

Disconnect the intake actuator connector.

3.

Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 4.

4.

Verify that the intake actuator operates to the fresh position when connecting in the reverse.

5.

Check the voltage between terminals 5 and 6.

Door position

Voltage (5-6)

Error detecting

Fresh

0.3 ± 0.15V

Low voltage :

0.1V or less

Recirculation

4.7 ± 0.15V

High voltage :

4.9V or more

It will feedback current position of actuator to controls.

6.

If the intake actuator is not operated well, substitute with a known-good intake actuator and check for proper operation.

7.

If the problem is corrected, replace the intake actuator.