Self-diagnosis process
How to read self-diagnostic code
After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format.
Fault code | Fail description | |
Control unit | DTC | |
00 | - | Normal |
11 | B1234 | In-car temperature sensor open |
12 | B1233 | In-car temperature sensor short |
13 | B1238 | Ambient temperature sensor open |
14 | B1237 | Ambient temperature sensor short |
17 | B1242 | Evaporator temperature sensor open |
18 | B1241 | Evaporator temperature sensor short |
19 | B1245 | Temperature control actuator feed back open |
19 | B1246 | Temperature control actuator feed back short |
20 | B2406 | Temperature control actuator failure |
21 | B1249 | Mode control actuator open |
21 | B1250 | Mode control actuator short |
22 | B2409 | Mode control actuator failure |
25 | B1208 | Intake potentiometer open |
25 | B1209 | Intake potentiometer short |
26 | B2408 | Intake potentiometer failure |
Fault code display
Continuance operation
Continuance operation : DTC code is more two
Step operation
Nomal or one fault code is same a continuance operation.
DTC code is more two.
If fault codes are displayed during the check, Inspect malfunction causes by referring to fault codes.
Fail safe
Incar sensor : Control with the value of 23°C(73.4°F)
Ambient temperature sensor: Control with the value of 20°C(67°F)
Evaporator temperature sensor: Control with the value of -2°C(28.4°F)
Temperature control actuator (Air mix potentiometer):
If temperature setting LO-24.5°C, fix at maximum cooling position.
If temperature setting 25°C-HI, fix at maximum heating position
Mode control actuator (Direction potentiometer):
Fix vent position, while selecting vent mode.
Fix defrost position, while selecting all except vent mode.
Intake control actuator :
Fix fresh position, while selecting fresh mode.
Fix recirculation position, while selecting recirculation mode.
Disconnect the negative (-) battery terminal.
Put the SST (A) into the space betwen the center facia (B).
Disconnect the connectors (A) from the center facia.
Remove the Heater & A/C controller (A) after loosening 4 screws.
Installation is the reverse order of removal.