Inspection
1.

Immerse the thermostat in water and gradually heat the water.

2.

Check the valve opening temperature.

Valve opening temperature : 85±1.5°C (185±34.7°F)

Full opening temperature : 95°C (203°F)

If the valve opening temperature is not as specified, replace the thermostat.

3.

Check the valve lift.

Valve lift : 8mm(0.3in) or more at 95°C (203°F)

If the valve lift is not as specified, replace the thermostat.