Inspection
1.

Ignition "OFF"

2.

Disconnect the connector of temperature control actuator.

3.

Verify that the temperature control actuator operates to the hot position when connecting 12V to the terminal 3 and grounding terminal 4.

Verify that the temperature control actuator operates to the cool position when connecting in the reverse.

[Drive]
A.

-

B.

-

C.

Cool position

D.

5V (Vcc)

E.

Feedback signal

F.

Senser GND

G.

Warm position

4.

Check the voltage between terminals 5 and 6.

[Specification]

Door position

Voltage (5-6)

Error detecting

Max. cooling

0.3 ± 0.15V

Low voltage : 0.1V or less

Max. heating

4.7 ± 0.15V

High voltage : 4.9V or more

* It will feedback current position of actuator to controls.

5.

If the measured voltage is not specification, substitute with a known-good temperature control actuator and check for proper operation.

6.

If the problem is corrected, replace the temperature control actuator.

[Passenger]
A.

-

B.

-

C.

Cool position

D.

5V (Vcc)

E.

Feedback signal

F.

Senser GND

G.

Warm position

7.

Check the voltage between terminals 5 and 6.

[Specification]

Door position

Voltage (5-6)

Error detecting

Max. cooling

0.3 ± 0.15V

Low voltage :0.1V or less

Max. heating

4.7 ± 0.15V

High voltage :4.9V or more

* It will feedback current position of actuator to controls.

8.

If the measured voltage is not specification, substitute with a known-good temperature control actuator and check for proper operation.

9.

If the problem is corrected, replace the temperature control actuator.