Ignition "OFF"
Disconnect the connector of mode control actuator.
Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3 and grounding terminal 4.
Verify that the mode control actuator operates to the vent mode when connecting in the reverse.
-
-
DEF
VENT
SENSOR GND
Feedback signal
5V (Vcc)
Check the voltage between terminals 5 and 6.
Door position | Voltage (5-6) | Error detecting |
Vent | 0.3 ± 0.15V | Low voltage : 0.1V or less |
Defrost | 4.7 ± 0.15V | High voltage : 4.9V or more |
It will feedback current position of actuator to controls.
If the measured voltage is not specification, substitute with a known-good console temp control actuator and check for proper operation.
If the problem is corrected, replace the console temp control actuator.