Component Location
General Description

Pressure Sensor is installed within Solenoid Valve Assay. Its role is to measure the pressure of the inner solenoid valve assay. As this sensor is pressured from the outside, an electrostatic capacity changes and this causes output's voltage to change. This sensor's output is analog signal which is in proportional to power supply and the control unit( ALS ECU ) recognizes the pressure value as a percentage of signal value against power supply.

DTC Description

The ALS ECU monitors the pressure sensor's signal and if it is out of normal range, this DTC is set.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Monitoring the voltage of pressure sensor

Open or short in the pressure sensor circuit

Faulty pressure sensor

Threshold value

When the Pressure sensor's output voltage is less than 0.1V or more than 4.85V during over 2 seconds

Fail-Safe

The self-leveling is enabled by the compressor

The warning lamp is activated.

Diagnostic Circuit Diagram