Component Location
General Description

TCM installed in inside Automatic transmissiom with E-module. Temperature sensor detects temperature increasing for inside of TCU and prevent from obnormal operation of TCU.

DTC Description

TCM set this code If Temperature sensor detects over 140℃.(MIL OFF)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Check signal range

Mechatronics (Valve-body + TCM)

Enable Conditions

"IG KEY" ON

Threshold Value

TCM Temperature > 140℃

Diagnostic Time

Immediately

Fail Safe

High speed : fixed at 5th gear, low speed : fixed at 3rd gear

Reverse : Shift lock(Push "Unlock button → possible to shift)

(priority :4)

caution
1)

The function with the higher priority will aiways take precedence. However, a low-priority is not overruled by a higher priority function.

2)

Functions from different priority categories can also run in parallel. It is important to note which function will take precedence in this case.

3)

In such an event it is possible for a substitute function with low priority not be carried out if a second, higher-priority function is present. This has been taken into account when compiling the priority list and is international.

4)

The mechanical emergency run function must always have the highest priority, since from the electrical standpoint it is the only safe condition.

Signal Waveform & Data

Fig 1) Temperature of TCU inside