Component Location
General Description

Pressure control solenoid valve make optimum oil pressure control oil pressure in Transmission. Pressure control solenoid valve decrease shift shock When engaging clutchs and brakes uses optimum oil pressure.

DTC Description

TCM set this code If detected open/short to ground in circuit.(MIL ON : 2 driving Cycle)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Short to Ground / Open

Mechatronics(E-module + Valvebody)

Enable Conditions

Power voltage > 8.7V

Voltage drop at FET ≤ 1V

Supply voltage ≥ 8.7V

Threshold Value

Short to Ground / Open

Diagnostic Time

0.05second

Fail Safe

high speed : fixed at 5th gear, low speed : fixed at 3rd gear.

Reverse : Shift lock(Push "Unlock button → possible to shift)

(priority : 3)

caution
1)

The function with the higher priority will aiways take precedence. However, a low-priority is not overruled by a higher priority function.

2)

Functions from different priority categories can also run in parallel. It is important to note which function will take precedence in this case.

3)

In such an event it is possible for a substitute function with low priority not be carried out if a second, higher-priority function is present. This has been taken into account when compiling the priority list and is international.

4)

The mechanical emergency run function must always have the highest priority, since from the electrical standpoint it is the only safe condition.

Signal Waveform & Data

Fig 1) Pressure control solenoid valve