Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Go to "Right Turn Signal Lamp Circuit Inspection" procedure.

Right Turn Signal Lamp Circuit Inspection
■ Check short to ground in harness
1.

IG "OFF" or IG "ON" & ENG "OFF"

2.

Disconnect FAM connector.

3.

Measure resistance between the right turn signal lamp terminal of FAM harness connector and ground of the right turn signal lamp.

Specification: Approx. 1 Ω

4.

Is the measured resistance within specification?

▶ Substitute with a known - good FAM and check for proper operation.

If the problem is corrected, replace the FAM and go to "Verification of Vehicle Repair" procedure.

▶ Repair open in circuit of Right Turn Signal Lamp or Right Turn Signal Lamp internal open, and go to "Verification of Vehicle Repair" procedure.

Яндекс.Метрика