The temperature control actuator is located at the heater unit. The actuator consists of a motor and feedback potentiometer that is used by the A/C ECU to control air temperature and to monitor actuator operation.
Airconditioner Control Module sets DTC B1205 if the Feed Back signal of Passenger Air mix actuator(Temperature actuator) has been detected over 4.9V for 100ms.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Voltage check |
•
Short to battery in signal(Feedback) circuit
•
Faulty passenger air mix actuator
•
Faulty A/C control unit |
Enable Conditions |
•
IG KEY ON | |
Threshold value |
•
Feedback ciruit has been detected over 4.9V for 100ms | |
Failsafe |
•
setting temperature : 24.5℃(76.1℉) fix at max. cooling position
•
setting temperature : 25℃(77℉) fix at max. heating position |
Door position | Voltage |
Max. cool | 0.3±0.15V |
Max. warm | 4.7±0.15V |