Component Location
General Description

Coolant temperature is detected by a water temperature sensor located at the heater unit. The A/C ECU uses coolant temperature to control the cold engine lockout function. The cold engine lockout function reduces blower speed until coolant temperature reaches the threshold value.

DTC Description

Air conditioner Control Module sets DTC B1202 if water temperature sensor has been detected over 4.9V for 4 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

Poor connection in wireharness

Open in signal circuit

Short to battery in signal circuit

Faulty Water temperature sensor

Faulty Air conditioner Control Module

Enable Conditions

IG KEY ON

Threshold value

Water temperature sensor has been detected over 4.9V for 4 seconds.

Failsafe

Control with the value of 85℃(185℉).

Specification
※ Resistance value of Water temperature sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/14

55.8

40/104

5.3

0/32

32.9

60/140

2.4

20/68

12.5

80/176

1.2