Componet Location
General Description

The mode control actuator is mounted at the heater control unit. The mode control actuator consists of a motor and a feedback potentiometer. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.

DTC Description

B2409 will set if the mode actuator has not responded to an A/C ECU actuation signal for over 40 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage check

•

Poor contact in harness

•

Open or short in motor power circuit

•

Faulty Driver Direction actuator

•

Faulty air conditioner control module

Enable Conditions

•

IG KEY ON

Threshold value

•

No movement to controlled mode position for 40 seconds

Failsafe

•

Fixed as current position

Specification
※ Voltage value of potentiometer as a function of mode door position.

Mode Door Position

Voltage

VENT

0.4±0.3V

BI-LEVEL

1.45±0.3V

FLOOR

2.5±0.3V

MIX

3.55±0.3V

DEF

4.6±0.3V

Diagnostic Circuit Diagram