Monitor Scantool data
■ Check Actuation Test
1.

Connect diagnostic tool to the DLC.

2.

Warm up the engine to normal temperature after engine start

3.

Select " Intake Potentiometer " parameter on the current data with scantool

4.

Perform Actuation Test for Air Inlet Mode Selection - Reculation /Fresh in order.

5.

During the actuation test, verify the position sensor data.

Specification : Recirculation : About 90%, Fresh : About 10%.

6.

Does the position sensor data change when performing the actuation test?

▶ This is a intermittent problem caused by poor contact of component or Control Unit

▶ Thoroughly check the looseness, poor connection, bent, corrison, contamination, deformation or damage of connector.

▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedure.

▶ Go to " Inspection/Repair " procedure.