IG key OFF.
Disconnect RPS connector, APS connector and BPS connector.
Check that sensor connector power supply is within the specification after turning IG key ON.
Connect RPS connector and APS connector, BPS connector in turn.
Measure the voltage of power circuit of each sensor with all connector connected.
Specification : Sensor power supply should not change as connecting RPS connector, APS connector, BPS connector. ☞ If the change of sensor power supply occur as connecting sensor connector, this means the occurrence of short inside of sensor.
Does change of sensor power supply occur as connecting sensor connector?
![]() | ▶ Replace related sensors.(RPS/APS/BPS) |
![]() | ▶ Go to "Verification of Vehicle Repair" procedure. |