Component Inspection
■ Check ECTS resistance
1.

IG key OFF.

2.

Disconnect ECTS connector.

3.

Check resistance between 'Signal' terminal and 'Ground' terminal of 'ENGINE COOLANT TEMPERATURE SENSOR' connector. (ECTS component side)

Specification :

Temp.

Resistance

Temp.

Resistance

- 40℃

48.14㏀

60℃

0.59㏀

- 20℃

14013 ~ 16.83㏀

80℃

0.32㏀

0℃

5.79㏀

100℃

0.19㏀

20℃

2.31 ~ 2.59㏀

110℃

0.145 ~ 0.149㏀

40℃

1.15㏀

120℃

0.116㏀

4.

Is the measured value within specification?

▶ Go to "Verification of Vehicle Repair" procedure.

▶ Replaces ECTS, and go to "Verification of Vehicle Repair" procedure.