Component Location
General Description

VGT(Variable Geometric Turbocharger) is the device which increases the efficiency of turbocharger at low rpm and lasts optimum turbo efficiency at high rpm as varying the cross sectional area through which exhaust gas passes turbocharger impeller. It relieves turbo lag at low speed and increase engine power generation.

The electronic VGT adapted on S engine is activated by VGT actuator control unit and electronic actuator integrated with DC motor. Engine speed, APS signal, MAFS and Boost pressure sensor data are inputted to ECM. ECM controls VGT actuator control unit to control exhaust gas line as controlling VGT actuator duty to maintain optimum state of air compression. VGT actuator control unit controls DC motor with those signal so that exhaust gas can pass through the vane more or less cross sectional with operating spear gear→outter crank→ inner crank→main link→ unison ring→inner vane in order.

VGT actuator control unit judges that actuator is faulty by feed back signal of actuator position from turbo charger position sensor. If it is detected, VGT actuator control unit notifies faulty to ECM. The electronic actuator is much faster in operating response and stable in control than vacuum type.

warning

In case of replacing E-VGT, perform the "COMPONENT CHANGE ROUTINE" procedure with scan tool. If the "COMPONENT CHANGE ROUTINE" procedure has not completed until automatic learning completed, it may cause vehicle performance and exhaust gas problem.

DTC Description

P0237 is set when BPS output voltage is lower than minimum value (200mV) for more than 2 sec.. This code is due to 1) open in power circuit or 2) short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage Monitoring

BPS circuit

BPS

Enable Conditions

IG key ON

Threshold Value

Output voltage is lower than minimum value (200mV).

- Open in power circuit.

- Short to ground in signal circuit.

Diagnostic Time

2 sec.

Fail Safe

Fuel cut

NO

Fixed at 900 hpa.

EGR Off

YES

Fuel Limit

YES

Check Lamp

OFF

Specification

Pressure

70 [㎪]

140 [㎪]

210 [㎪]

270 [㎪]

18℃~28℃

Output voltage

1.02 ~ 1.17 [V]

2.13 ~ 2.28 [V]

3.25 ~ 3.40 [V]

4.20 ~ 4.35 [V]

Diagnostic Circuit Diagram
Signal Waveform & Data

Fig.1) The waveform of BPS signal and APS signal as accelerating from idle state. Signal voltage rises as accelerating.