Monitor GDS Data
1.

Connect GDS with 'DATA LINK CONNECTOR'(DLC).

2.

Warm engine up to normal operating temperature.

3.

Turn all the electrical devices including air conditioner OFF.

4.

Monitor "VGT ACTUATOR." parameter on the GDS.

Specification : 50 ~ 95 % at idle

Fig. 1) Sensor data when variable swirl valve closed at idle.

Fig. 2) Sensor data when variable swirl valve opened at acceleration.

Яндекс.Метрика