Scantool Data Analysis
1.

Connect GDS.

2.

IG "ON" and engine "OFF".

3.

Select "DTC Analysis" mode.

4.

After erase DTC, keep the vehicle condition within "the enable conditions" (Refer to "DTC Detecting Condition" table).

5.

Is the same DTC occurred again?

▶ Go to next procedure.

▶ Fault is intermittent caused by poor contact in the components and/or RAM's connector or was repaired and RAM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

■ Check Rear Blower Switch Illumination
6.

IG "OFF" and connect scantool

7.

IG "ON" & ENG "OFF"

8.

Select "Actuation Test" mode.

9.

Execute "Rear Blower Switch Illumination" test.

10.

Is the service data normal?

▶ Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Go to next procedure.

Яндекс.Метрика