Component Location
General Description

The automatic transmission fluid(ATF) temperature sensor A is installed in the Transmission Range Switch and fluid(ATF) temperature sensor B is installed in the valve body. The TCM supplies a 5V reference voltage to the sensor, and the output voltage of the sensor changes when the ATF temperature varies.

DTC Description

This DTC is for checking sensor failure. This code is set if the temperture data from Oil Temperture sensor is fixed between -20℃ and 0℃ or 0℃ and 20℃ for 10min. after driving a vehicle.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Circuit continuty-ground

※ ATF T/S :Automatic Transmission Fluid Temperature Sensor

•

Short to ground in circuit

•

Faulty ATF T/S 1

•

TCM

Enable Conditions

•

Battery voltage > 10V

Threshold Value

•

Input voltage < 0.05V

Diagnostic Time

•

More than 2 sec

Fail Safe

•

OTS2 temperature(If OTS2 is error, 80['C] is fixed)

•

Shift prevention over 4th gear

•

Prevention of manual shift

•

Prevention of pressure adaptation

Specification

Temperature(℃)

Resistance(KΩ)

Voltage(V)

ATF T/S 1

0℃

Approx. 15KΩ

Approx. 3.3V

20℃

Approx. 6.5KΩ

Approx. 2.7V

80℃

Approx. 0.9KΩ

Approx. 0.9V

ATF T/S 2

0℃

Approx. 10.5KΩ

Approx. 3.3V

20℃

Approx. 4.3KΩ

Approx. 2.5V

80℃

Approx. 0.5KΩ

Approx. 0.7V

Diagnostic Circuit Diagram