Terminal and Connector Inspection
1.

Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Go to "Right Turn Signal Lamp Circuit Inspection" procedure.

Right Turn Signal Lamp Circuit Inspection
■ Check short to ground in harness
1.

IG "OFF" or IG "ON" & ENG "OFF"

2.

Disconnect FAM, Right Turn Signal Lamp connector.

3.

Measure resistance between the right turn signal lamp terminal of FAM harness connector and chassis ground.

Specification: infinity

4.

Is the measured resistance within specification?

▶ Substitute with a known - good FAM and check for proper operation.

If the problem is corrected, replace the FAM and go to "Verification of Vehicle Repair" procedure.

▶ Repair short to ground in circuit of Right Turn Signal Lamp, and go to "Verification of Vehicle Repair" procedure.