TCM installed in inside Automatic transmissiom with E-module. Temperature sensor detects temperature increasing for inside of TCU and prevent from obnormal operation of TCU.
TCM set this code If output value of Temperature sensor out of normal range or not changed for long term. (MIL OFF)
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Check signal range |
•
Faulty in Mechatronics (Valve-body + TCM) |
Enable Conditions |
•
"IG KEY" ON | |
Threshold Value |
•
Output value of Temperature sensor out of normal range
•
Output value of Temperature sensor not changed for long term | |
Diagnostic Time |
•
1.5 second | |
Fail Safe |
•
-
•
(priority : 2) |
The function with the higher priority will aiways take precedence. However, a low-priority is not overruled by a higher priority function.
Functions from different priority categories can also run in parallel. It is important to note which function will take precedence in this case.
In such an event it is possible for a substitute function with low priority not be carried out if a second, higher-priority function is present. This has been taken into account when compiling the priority list and is international.
The mechanical emergency run function must always have the highest priority, since from the electrical standpoint it is the only safe condition.
Fig 1) Temperature of TCU inside