Component Location
General Description

The PCM/TCM controls the locking and unlocking of the Torque Converter Clutch ( or Damper Clutch ), to the input shaft of the transmission, by appling hydraulic pressure. The main purpose of T/C clutch control is to save fuel by decreasing the hydraulic load inside the T/C. The PCM/TCM outputs duty pulses to control the Damper Clutch Control Solenoid Valve( DCCSV ) and hydraulic pressure is applied to the DC according to the DCC duty ratio value. When the duty ratio is high, high pressure is applied and the Damper Clutch is locked.

DTC Description

TCM set this code If detected short to battery for Torque convertor clutch solenoid.(MIL ON : 2 driving Cycle)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Short to battery

Mechatronics(E-module + Valvebody)

Enable Conditions

Supply voltage > 8,7V

Threshold Value

Short to battery

Diagnostic Time

0.05second

Fail Safe

No Torque convertor clutch control

No learning control

(priority : 3)

caution
1)

The function with the higher priority will aiways take precedence. However, a low-priority is not overruled by a higher priority function.

2)

Functions from different priority categories can also run in parallel. It is important to note which function will take precedence in this case.

3)

In such an event it is possible for a substitute function with low priority not be carried out if a second, higher-priority function is present. This has been taken into account when compiling the priority list and is international.

4)

The mechanical emergency run function must always have the highest priority, since from the electrical standpoint it is the only safe condition.

Signal Waveform & Data
Solenoid valve operating status according to gear position

gear

position

ON SOL.

SOL.1

SOL.2

SOL.3

SOL. 4

SOL. 5

SOL. 6

P

OFF

48mA

848mA

48mA

48mA

-O-

OFF

R

OFF

48mA

48mA

48mA

48mA

-O-

OFF

N

OFF

48mA

848mA

48mA

48mA

-O-

OFF

D1

OFF

848mA

848mA

48mA

48mA

-O-

-O-

D2

OFF

848mA

848mA

848mA

848mA

-O-

-O-

D3

OFF

848mA

48mA

48mA

848mA

-O-

-O-

D4

ON

848mA

848mA

48mA

48mA

-O-

-O-

D5

ON

48mA

48mA

48mA

48mA

-O-

-O-

D6

ON

48mA

848mA

848mA

48mA

-O-

-O-

-O- : variable control

Fig 1) Lock-up status of Torque convertor clutch in 3rd gear.

Fig 2) Release the Lock-up at 3rd to 4th gear shifting

Fig 3) Release the Lock-up status in 5th gear

Fig 4) Lock-up status in 5th gear

Fig 5) Lock-up status in 6th gear