Component Location
General Description

Shift control solenoid valve is not supply oil pressure usually,TCM output electric signal to solenoid valve then oil pressure supplied to Clutch "A". Solenod3(Brake C), Solenod6(Torque convertor clutch) are same type solenoid valve.

DTC Description

TCM set this code If detected short to battery for solenoid valve circuit.(MIL ON : 2 driving Cycle)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Short to battery

Mechatronics(E-module + Valvebody)

Enable Conditions

Supply voltage > 8,7V

Threshold Value

Short to battery

Diagnostic Time

0.05second

Fail Safe

Maximum line pressure control(D : 14kg/㎠, R : 20kg/㎠)

No learning control

(priority : 3)

caution
1)

The function with the higher priority will aiways take precedence. However, a low-priority is not overruled by a higher priority function.

2)

Functions from different priority categories can also run in parallel. It is important to note which function will take precedence in this case.

3)

In such an event it is possible for a substitute function with low priority not be carried out if a second, higher-priority function is present. This has been taken into account when compiling the priority list and is international.

4)

The mechanical emergency run function must always have the highest priority, since from the electrical standpoint it is the only safe condition.

Signal Waveform & Data

Fig 1) Shift control solenoid valve