Component Location
General Description

Shift control solenoid valve is supply oil pressure usually,TCM output "ON" signal to solenoid valve then oil pressure not supplied to Clutch "B". Solenod4(Clutch E & Brake D), Solenod5(Line pressure) are same type solenoid valve.

If electrical power source not spplied to all of solenoid valve, the oil pressure supplied to 3 solenoid valves and shift gear is fixed at 3rd gear as mechanical operation.

DTC Description

TCM set this code If detected short to ground / open for solenoid valve cirduit.(MIL ON : 2 driving Cycle)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Short to ground / open

Mechatronics(E-module + Valvebody)

Enable Conditions

Voltage drop at the voltage regulator ≤ 1V

Supply voltage ≥ 8.7V

Threshold Value

Short to ground / open

Diagnostic Time

0.05second

Fail Safe

High speed : fixed at 5th gear, low speed : fixed at 3rd gear.

Reverse : Shift lock(Push "Unlock button → possible to shift)

(priority : 3)

caution
1)

The function with the higher priority will aiways take precedence. However, a low-priority is not overruled by a higher priority function.

2)

Functions from different priority categories can also run in parallel. It is important to note which function will take precedence in this case.

3)

In such an event it is possible for a substitute function with low priority not be carried out if a second, higher-priority function is present. This has been taken into account when compiling the priority list and is international.

4)

The mechanical emergency run function must always have the highest priority, since from the electrical standpoint it is the only safe condition.

Signal Waveform & Data

Fig 1) Shift control solenoid valve