Monitor Scantool Data
1.

Connect scantool to data link connector(DLC).

2.

Ignition "ON" & Engine "OFF".

3.

Monitor the "Inhibitor s/w" parameter on the scantool.

4.

Move selector lever from "P" range to "D" range.

Fig 1) Working status of Inhibitor s/w

5.

Does "Inhibitor s/w" follow the reference data?

▶ Fault is intermittent caused by poor contact in the sensor's and/or TCM(PCM)'s connector or was repaired and TCM(PCM) memory was not cleared. Throughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration or damage.Repair or replace as necessary and go to "Verification Vehicle Repair" procedure.

▶ Go to "Component Inspection" procedure.