Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the OCV connector.

3.

Measure resistance between the OCV terminals 1 and 2.

4.

Check that the resistance is within the specification.

Specification: Refer to Specification Section.

Removal
[CVVT Oil Control Valve (Bank 1)]
1.

Turn ignition switch OFF and disconnect the negative (-) battery cable.

2.

Disconnect the CVVT oil control valve connector (A-Intake) and (B-Exhaust).

3.

Remove the cylinder head cover and the timing chain upper cover. [Bank 1]

(Refer to "Cylinder Head Assembly" in EM group)

4.

Remove the mounting bolt (C), and then remove the valve from the engine.

[CVVT Oil Control Valve (Bank 2)]
1.

Turn ignition switch OFF and disconnect the negative (-) battery cable.

2.

Disconnect the CVVT oil control valve connector (A-Intake) and (B-Exhaust).

3.

Remove the cylinder head cover and the timing chain upper cover. [Bank 2]

(Refer to "Cylinder Head Assembly" in EM group)

4.

Remove the mounting bolt (C), and then remove the valve from the engine.

Installation
1.

Installation is the reverse of removal.

CVVT oil control valve installation bolt:

9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

caution

Pay attention to color of valve connector (Harness side) when installing.

If an OCV is installed on opposite manifold, the engine may be damaged.

[Connector Color]

Item

Component Side

Harness Side

Intake

Black

Gray

Exhaust

Black

Black