The Evaporator sensor is a negative temperature coefficient thermistor that is mounted at the evaporator core. The A/C ECU uses the evaporator sensor data to control A/C compressor operation in order to prevent evaporator freezing.
Air conditioner Control Module sets DTC B1241 if Evaporator sensor has been detected below 0.1V for 4 seconds.
Item  | Detecting Condition  | Possible Cause  | 
DTC Strategy  | 
										•
									 Voltage check  | 
										•
									 Short circuit in harness 
										•
									 Faulty Evaporator sensor 
										•
									 Faulty A/C Control Unit  | 
Enable Conditions  | 
										•
									 IG KEY ON  | |
Threshold value  | 
										•
									 Evaporator sensor has been detected below 01.V for 4 seconds.  | |
Failsafe  | 
										•
									 Control with the value of -2℃(28.4℉)  | 
Temperature(℃/℉)  | Resistance(㏀)  | Temperature(℃/℉)  | Resistance(㏀)  | 
-10/-14  | 18  | 20/68  | 4.8  | 
0/32  | 11  | 30/86  | 3.3  | 
10/50  | 7.3  | 40/104  | 2.3  |