The mode control actuator is mounted at the heater control unit. The mode control actuator consists of a motor and a feedback potentiometer. Pressing mode select switch makes the mode control actuator shift in order of vent→ B/L → floor → mix.
B2409 will set if the mode actuator has not responded to an A/C ECU actuation signal for over 40 seconds.
Item  | Detecting Condition  | Possible Cause  | 
DTC Strategy  | 
										•
									 Voltage check  | 
										•
									 Poor contact in harness 
										•
									 Open or short in motor power circuit 
										•
									 Faulty Driver Direction actuator 
										•
									 Faulty air conditioner control module  | 
Enable Conditions  | 
										•
									 IG KEY ON  | |
Threshold value  | 
										•
									 No movement to controlled mode position for 40 seconds  | |
Failsafe  | 
										•
									 Fixed as current position  | 
Mode Door Position  | Voltage  | 
VENT  | 0.4±0.3V  | 
BI-LEVEL  | 1.45±0.3V  | 
FLOOR  | 2.5±0.3V  | 
MIX  | 3.55±0.3V  | 