Inspection
[Non-Adjust type]
1.

Connect a scantool on the Data Link Connector (DLC).

2.

Turn the ignition switch ON.

3.

Measure the output voltage of the APS 1 and 2 at C.T and W.O.T.

Specification: Refer to Specification Section.

[Adjust type]
1.

Connect a scan tool to the Diagnoisis Link Connector (DLC).

2.

Start engine and check output voltages of APS 1 and 2 at C.T and W.O.T.

Specification

Accelerator

Position

Output Voltage (V)

APS1

APS2

C.T

0.7 ~ 0.8V

0.29 ~ 0.46V

W.O.T

3.85 ~ 4.35V

1.93 ~ 2.18V

3.

Turn ignition switch OFF and disconnect the scantool from the DLC.

4.

Disconnect APS connector and measure resistance between APS terminals 4 and 5 (APS 1).

Specification: Refer to Specification Section.

5.

Disconnect APS connector and measure resistance between APS terminals 1 and 6 (APS 2).

Specification: Refer to Specification Section.