DTC Description

If measured temperature is lower than the minimum threshold value during 100sec, ECM sets DTC P0113.

(In this case, the input signal voltage is the maximum threshold vaue.)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal check, high

1.

Poor connection

2.

Open or short to power in signal circuit

3.

Open in ground circuit

4.

IATS

Enable Conditions

•

Elapsed time after start is higher than 2 sec.

Threshold Value

•

Measured temperature is lower than -45 ℃

Diagnostic Time

•

2 sec.

MIL ON Condition

•

2 Drive Cycle

Яндекс.Метрика