DTC Description

P0117 is set when the voltage below 200mV - minimum output voltage of ECTS - is detected for more than 2.0 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage monitoring

•

ECTS circuit

•

ECTS component

Enable Conditions

•

IG KEY "ON"

Threshold Value

•

Output signal below the minimum value.(below 200mV)

Diagnostic Time

•

2.0 sec.

Fail Safe

Fuel cut

NO

•

During engine operation : temperature is fixed at 80℃

at cranking : temperature is fixed at -10℃

EGR Off

YES

Fuel Limit

NO

Check Lamp

NO