DTC Description

A failure is detected if the output signal voltage of the pressure sensor is out of specified range.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

•

Voltage Monitoring

1.

Open or short of pressure sensor circuit

2.

Faulty pressure sensor

3.

Faulty HECU

Case 1

Monitoring Period

•

Continuous

Enable

Conditions

•

A sensor supply failure is detected if Sensor Supply Voltage shows under 4.75V or over 5.25V for 60ms.

Case 2

Monitoring Period

•

Continuous

Enable

Conditions

•

A Fault is set if the sensor values(PRS1,PRS2) keep under 0.6V or over 4.5V for 100ms.

- PRS1 : Sensor output 1

- PRS2 : Sensor output 2(Inverse image of PRS1)

Case 3

Monitoring Period

•

Continuous

Enable

Conditions

•

A Fault is set if the if sum of the sensor values(PRS1+PRS2) keep under 4.4V or over 5.4V

- PRS1 : Sensor output 1

- PRS2 : Sensor output 2(Inverse image of PRS1)

Fail Safe

•

The ABS/ESP(ESC) functions are inhibited

•

The ABS/ESP(ESC) warning lamps are activated