DTC Description

P0117 is set when the voltage below 250mV - minimum output voltage of ECTS - is detected for more than 3.27 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage monitoring

•

ECTS circuit

•

ECTS component

Enable Conditions

•

IG KEY "ON"

Threshold Value

•

Output signal below the minimum value.(below 250mV)

Diagnostic Time

•

3.27 sec.

Fail Safe

Fuel cut

NO

•

During engine operation : temperature is fixed at 90℃

EGR Off

NO

Fuel Limit

YES

Check Lamp

NO