DTC Description

DTC B1249 sets if the Mode Actuator Sensor signal is at or below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage check

1.

Poor Connection in harness

2.

Open in signal (Feedback signal), Power or Gruoud circuit

3.

Faulty Mode Actuator

4.

Faulty Air conditioner Control Unit

Enable Conditions

•

Ignition ON

Threshold value

•

Mode Actuator Sensor signal is at or below 0.1V for 0.3 seconds

Failsafe

•

If the Mode actuator is placed at Vent mode right before fail detection, Actuator is operated and fixed to Vent Mode Postion.

•

The others mode are selected, Actuator is moved to DEF mode position