Removal
note

Disassembly of the thermostat would have an adverse effect, causing a lowering of cooling efficiency.

1.

Drain the engine coolant so that its level would be under the thermostat height.

(Refer to Cooling System - "Coolant")

2.

Remove the radiator lower hose (A).

3.

Remove the water inlet fitting (A) and thermostat (B).

Tightening torque :

18.6 ~ 23.5 N.m (1.9 ~ 2.4 kgf.m, 13.7 ~ 17.4 lb-ft)

4.

Install in the reverse order of removal.

note

Place the thermostat with the jiggle valve (C) upward.

5.

Fill with the engine coolant.

(Refer to Cooling System - "Coolant")

6.

Start engine and check for leaks.

Inspection
1.

Immerse the thermostat in water and gradually heat the water.

2.

Check the valve opening temperature.

Valve opening temperature:

82±1.5°C (179.6±2.7˚F)

Full opening temperature: 95°C (203˚F)

If the valve opening temperature is not as specified, replace the thermostat.

3.

Check the valve lift.

Valve lift : 8mm(0.3in) or more at 95°C (203˚F)

If the valve lift is not as specified, replace the thermostat.