Inspection
First Seat Heater
1.

Check for continuity and measure the resistance between terminals.

No.

Description

No.

Description

1

Heater(-)

3

NTC(+)

2

NTC(-)

4

Heater(+)

Standard value

Cushion : 1.08 Ω ± 10%

Back: 1.13 Ω ± 10%

Set : 2.26 Ω ± 10%

2.

Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.

Standard value (Fabric / Leather)

Cushion :

High : 40 ± 2°C (104 ± 3.6°F)

Low : 38 ± 2°C (100.4 ± 3.6°F)

Middle : 36 ± 2°C (96.8 ± 3.6°F)

Back :

High : 46 ± 2°C (114.8 ± 3.6°F)

Low : 43 ± 2°C (109.4 ± 3.6°F)

Middl : 40 ± 2°C (104 ± 3.6°F)