Installation
caution
●

Install the component with the specified torques.

●

Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.

caution
●

Be careful not to damage the sensing element and the honey cell.

1.

Installation is reverse of removal.

IATS #1 installation bolt:

3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)

IATS #1 clamp installation screw:

2.9 ~ 4.9 N.m (0.3 ~ 0.5 kgf.m, 2.2 ~ 3.6 lb-ft)

IATS #2 installation bolt:

6.9 ~ 10.8 N.m (0.7 ~ 1.1 kgf.m, 5.1 ~ 8.0 lb-ft)