Inspection
1.

Turn ignition switch OFF.

2.

Disconnect the VGT control solenoid valve connector.

3.

Measure resistance between terminal 1 and 2 of the valve.

4.

Check that the resistance is within the specification.

Specification: Refer to Specification section.

Removal
1.

Turn ignition switch OFF.

2.

Disconnect the VGT control solenoid valve connector (A).

3.

Remove the VGT control solenoid valve (D) after removing the installation bolt (B) and hose (C).

Installation
1.

Install is reverse of removal.