Inspection
1.

Turn ignition switch OFF.

2.

Disconnect the EEGR valve connector.

3.

Check that the EEGR valve is stuck by foreign material.

4.

Measure resistance between motor (+) and (-) control terminals of the motor.

5.

Check that the resistance is within the specification.

Specification: Refer to “Specification” section.

6.

Measure resistance between voltage supply terminal and ground terminal of the position sensor.

7.

Check that the resistance is within the specification.

Specification: Refer to “Specification” section.

Removal
1.

Turn the ignition switch OFF and disconnect the battery (-) cable.

2.

Disconnect the EEGR valve connector (A).

3.

Remove the intercooler hose and pipe (B) after removing the installation bolt (A).

4.

Remove the EEGR valve (D) after removing the installation bolts (A,B,C).

Installation
caution

Install the component with the specified torques.

Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.

1.

Installation is reverse of removal.

Electric EGR control valve installation bolt:

21.6 ~ 27.5 N.m (2.2 ~ 2.8 kgf.m, 15.9 ~ 20.3 lb-ft)