DTC Description

If there is not any signal activity, ECM sets DTC P0140.

(This DTC might be caused by the malfunction of Heater circuit, so, check the heater circuit first.)

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal no activity detect

1.

Poor connection

2.

Open or short in signal circuit

3.

S2

General

Enable

Conditions

•

Dew point end detected

•

Fuel feed back control active

•

Battery voltage is higher than 11V

•

Exhaust Gas temperature is higher than 350℃ and lower than 800℃

•

No upstream O2 sensor heater error

•

Oscillation Test not completed

•

Time duration for Target lamba = 0.9 (15 sec.)

•

Lambda feed back control value = 0.95~1.05

•

Rear O2 sensor heater monitoring - completed

Threshold Value

•

Sensor voltage is lower than 0.65V

Diagnostic Time

•

315 sec.

MIL ON Condition

•

2 driving cycle