DTC Description

P0606 is set when 1) writing/reading error inside of ECM occur. 2) error of APS 2 ground checking which is repeated every 0.2 sec. or 3) the voltage of sensor power supply 1 and 2 (the standard voltage of A/D converter) are below 4.7V or above 5.1V. This code is due to ECM internal failure.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Signal monitoring

•

ECM component failure

Enable Conditions

•

IG KEY "ON"

Threshold Value

•

writing/reading error inside of ECM

•

APS 2 ground checking error

•

APS 2 ground checking error

Diagnostic Time

•

Immediately

Fail Safe

Fuel cut

YES

EGR Off

NO

Fuel Limit

NO

MIL

YES