DTC Description

If sensor signal input is lower than 0.3V during 0.5 sec, ECM sets DTC P0192.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Signal check, low

1.

Poor connection

2.

Open or short to ground in power circuit

3.

Short to ground in signal circuit

4.

FPS

Enable Conditions

IG ON

Threshold Value

Sensor voltage is lower than 0.3 V

Diagnostic Time

0.5 sec.

MIL ON Condition

2 driving cycle