DTC Description

If low battery voltage is detected for more than 2 sec., ECM sets DTC P056200. This fault might be caused by defected battery or faulty power circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

1.

Poor connector connection

2.

Faulty charging system

3.

Faulty alternator

4.

Faulty battery

5.

Faulty ECM

Enable Conditions

Engine running

Threshold Value

Low battery voltage is detected

Diagnostic Time

2 sec.

Fail Safe

MIL

Off