DTC Description

This code is set when the Front RH turn signal lamp circuit is open while the RH turn signal lamp is operating.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Load Monitoring

1.

Poor connection

2.

Open Circuit in Front RH turn signal lamp

3.

Faulty Front RH turn signal lamp

4.

Faulty SJB

Enable Conditions

•

Ignition "ON"

Threshold Value

•

Front RH turn signal lamp Circuit Open

Diagnostic Time

•

0.12 sec Retry 2 Times Detection

DTC Erasing Time

•

DTC can be erased immediately with GDS after fault has been fixed.

•

Normal condition after IG "ON"