DTC Description

This code is set when the Front LH turn signal lamp circuit is shorted to ground while the LH turn signal lamp is operating.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Load Monitoring

1.

Poor connection

2.

Short to Ground in Front LH Turn Signal Lamp

3.

Faulty Front LH Turn Signal Lamp

4.

Faulty SJB

Enable Conditions

Ignition "ON" (Hazard = Battery(+))

Threshold Value

Front LH Turn Signal Lamp Circuit is Shorted to Ground

Over Current

Diagnostic Time

0.12 sec Retry 2 Times Detection

DTC Erasing Time

DTC can be erased immediately with GDS after fault has been fixed.