This code is set when the LH head lamp low circuit is shorted to ground while the LH head lamp low is operating.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Load Mornitoring | 1. Poor connection 2. Short to Ground in Head Lamp Low LH Circuit 3. Faulty Head Lamp Low LH 4. Faulty SJB |
Enable Conditions |
•
Ignition "ON" | |
Threshold Value |
•
Head Lamp Low LH Circuit is Shorted to Ground
•
Over Current
•
Recovery retry for more than 3 times | |
Diagnostic Time |
•
0.12 sec Retry 10 Times Detection | |
DTC Erasing Time |
•
DTC can be erased immediately with GDS after fault has been fixed. |