This code is set when the RH DRL lamp circuit is shorted to ground while the RH DRL lamp is operating.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Load Mornitoring | 1. Poor connection 2. Short to ground in Dedicated DRL Lamp RH circuit 3. Faulty Dedicated DRL Lamp RH 4. Faulty SJB |
Enable Conditions |
•
IG KEY ON. | |
Threshold Value |
•
RH DRL lamp Circuit Short to Ground | |
Diagnostic Time |
•
It immediately sets DTC after fault detects. | |
DTC Erasing Time |
•
Present Failure : IGN SW OFF after fault has been fixed.
•
Memorized Failure : DTC can be erased immediately with GDS. |