DTC Description

This code is set when the RH DRL lamp circuit is shorted to ground while the RH DRL lamp is operating.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Load Mornitoring

1.

Poor connection

2.

Short to ground in Dedicated DRL Lamp RH circuit

3.

Faulty Dedicated DRL Lamp RH

4.

Faulty SJB

Enable Conditions

IG KEY ON.

Threshold Value

RH DRL lamp Circuit Short to Ground

Diagnostic Time

It immediately sets DTC after fault detects.

DTC Erasing Time

Present Failure : IGN SW OFF after fault has been fixed.

Memorized Failure : DTC can be erased immediately with GDS.